FVS-600-W ECO2SCHOOL

Decentralised school ventilation  - Controlled CO2 level without external noise and fine dust/pollen

For wall installation

The decentralised ventilation unit FVS Univent has been designed specifically to ventilate class and conference rooms or office spaces. Special features include high thermal comfort and low thermal heat requirement. 95% of inhalable fine dusts and 99% of pollen and coarse dusts are filtered. Improved indoor air quality may not only result in better school or workforce achievements but enhance the health conditions of employees and students as well.

For schools, maintaining good indoor air quality is essential. Need-controlled, automatic ventilation systems with heat recovery effectively reduce CO₂ levels, fine dust, and germ concentrations—ensuring a healthier and more productive environment while minimising primary energy consumption.

Sustainable room air technology not only promotes health and performance but also supports environmental protection. The FVS Univent, a decentralised, freely suspended ventilation unit with integrated air diffusers, offers a seamless solution. Its design eliminates the need for ceiling paneling and additional inspection openings, making it easy to retrofit gradually—perfect for installation during school holidays or weekends with minimal disruption.

Type FVS-600 for air flow rates up to 720m³/h. For increased air flow rates up to 990m³/h we recommend type FVS-1000.

  • Short length (3 m) with easy connection to the facade. 
  • Low-noise, virtually unperceivable sound pressure levels, e.g, 27dB(A) at 400m³/h / 6dB room absorption. 
  • Integrated compact silencer with enhanced low frequency attenuation. Lower primary energy requirement compared to traditional window ventilation due to:
  • energy-efficient and usage-dependent operation with  optimized fans and background control 
  • low energy consumption (130W at 680m³/h), meets SFP1 
  • Automatic air supply with CO2 control avoiding user errors. 
  • No mould formation. 
  • No condensate pipe required. 
  • High-efficient heat recovery (up to 83%) resulting in little need for heating the supplied air. 
  • Quick and easy installation, in case of retrofitting minimum disturbance of ongoing operations. 
  • High outside air flow rates (up to 720m3/h max).
  • Outside air module with weather protection grille, air tight outside air damper and excellent heat insulation. 
  • All-in-one solution with air conveyance system for speedy reduction of temperature differences and indoor air velocities. 
  • High sanitation standards thanks to:
  • simplified antifreeze protection without electric reheating 
  • heavy-duty air filters (supply air: F7, exhaust air: M5) 
  • humidity protection meeting VDI 6022 requirements