FVS-900-C ECO2SCHOOL
Decentralised school ventilation - Controlled CO2 level without external noise and fine dust/pollen
The decentralised ventilation unit FVS Univent has been designed specifically to ventilate class and conference rooms. Its special features include high thermal comfort and low thermal heat requirement. 95% of inhalable fine dusts and 99% of pollen and coarse dusts are filtered. Improved indoor air quality may not only result in better school achievements but enhance the health conditions of teachers and students as well.
For schools, a need-controlled, automatic ventilation including heat recovery is required to ensure good indoor air quality thanks to low CO2, fine dust and germ concentrations while keeping primary energy consumption low. Thus, sustainable room air technology makes a positive contribution to health, output and environmental protection. The freely suspended decentralised ventilation unit FVS Univent with integrated air diffusers makes the provision of ceiling panellings and additional inspection openings superfluous and may even be gradually retrofitted during holidays or on weekends.
Type FVS-900 for air flow rates up to 990m³/h; for ventilation of individual, connected rooms or utilisation units up to approx. 200m² floor area.
For lower air flow rates up to 720m³/h we recommend type FVS-600.
- Short length (3 m) with easy connection to the facade.
- Low-noise, virtually unperceivable sound pressure levels, e.g. 27dB(A) at 400m³/h / 6dB room absorption.
- Integrated compact silencer with enhanced low frequency attenuation. Lower primary energy requirement compared to traditional window ventilation due to:
- energy-efficient and usage-dependent operation with optimized fans and background control
- low energy consumption (130W at 680m³/h), meets SFP1.
- Automatic air supply with CO2 control avoiding user errors.
- No mould formation.
- No condensate pipe required
- High-efficient heat recovery (up to 86%) resulting in little need for heating the supplied air.
- Quick and easy installation, in case of retrofitting minimum disturbance of ongoing operations.
- High outside air flow rates (up to 990m3/h max.)
- Outside air module with weather protection grille, airtight outside air damper and excellent heat insulation.
- All-in-one solution with air conveyance system for speedy reduction of temp. differences and indoor air velocities.
- High sanitation standards thanks to:
- simplified antifreeze protection without electric reheating
- heavy-duty air filters (supply air: F7, exhaust air: M5)
- humidity protection meeting VDI 6022 requirements